Drainage Technology for Buildings, Agriculture and Landscaping
SIROBAU S 300
Drainage system to DIN 4095
Drainage system with modular inspection and flushing chamber of PE-HD for the protection of structures in accordance with DIN 4095
Application
In modern architecture basements of buildings are often designed for dwelling or storing in order to make best use of the available floor space. For this purpose, basements have to be permanently protected against moisture. The main reason for damp masonry is inadequate sealing and a missing drainage system.
The protection of structures in contact with soil should be in accordance with DIN 4095 with due regard being paid to the local soil conditions and occurrence of ground water, if any. To avoid soaking of the masonry and damages to the structure, a well-designed drainage system around the building for discharge of ground and percolating water is a must, as is adequate sealing of the outer walls in contact with soil. The SIROBAU S 300 drainage system meets all requirements of DIN 4095. Architects, building owners and building contractors profit from the system’s advantages in quality and its reliable operation.
Professional sealing and a reliably working building drainage keep cellar rooms permanently dry.
- Drainage of structures in contact with soil in accordance with DIN 4095 (building drainage)
- Drainage systems in gardening, landscaping and sports fields
- Inspection and flushing chamber to DIN 4095
- Made of PE-HD in twin wall design (outside corrugated/inside smooth)
- Ring stiffness S ≥ 8.0 kN/m2 to DIN EN ISO 9969 (SN 8)
- Components of the drainage system
- SIROBAU S 300 inspection and flushing chamber
- SIROBAU-/SIROPLAST-K civil engineering drainage pipes to DIN 4262-1
- Quality-assured by SKZ, test and inspection mark A 376
- Robust chamber design
- Excellent axial stiffness
- High impact resistance up to –40 °C
- Chamber inside diameter of di ≥ 300 mm complying with the standard (DIN 4095)
- Chamber outlet adaptors with special locking technique
- Standard-compliant pipe insertion depth according to DIN 4262-1 with pipe stop – no pipes protruding into the chamber
- Easy handling
- Low weight
- Two chamber variants (with/without sand trap)
- High stability without additional filling material required inside the chamber
- High impact resistance – rupture-proof, even at low temperatures
- Proven inspection possibility
- Long service life
- Extensive range of accessories/variety of combinations
Download area
- Leaflets|
- Product specifications|
- Design drawings